日本熟妇一区二区三区,亚洲一区人妻在线,亚洲色在线九九久,女女亚成区视频,91久久精,日韩天堂久久在线,婷婷精品视频五区在线,五十路无码,久国产精品区

199-3021-7010

The 3051 pressure transmitter may cause errors and solutions in transmission

The 3051 Pressure Transmitter can cause errors in pressure transmission for the following reasons: 1. Leakage; 2. Friction loss; 3. Liquid pipeline accumulation gas (indenter error); 4. Liquid accumulation in gas pipeline (indenter error); 5. The density change caused by the temperature difference between the two impulse tubes (indenter error). 3051 Pressure Transmitter Pressure Transmission Reduction Error: 1. The impulse tube should be as short as possible; 2. For liquid or steam measurement, the impulse pipeline should be connected upward to the process pipeline, and its inclination should not be less than 1/12; 3. For the gas impulse pressure pipe, it should be connected downward, and the inclination should not be less than 1/12; 4. The measurement point of the liquid process pipeline should be lower, and the gas pipeline point should be higher; 5. The two impulse tubes should maintain the same temperature; 6. In order to avoid the influence of friction, the diameter of the impulse pipe should be large enough; 7. Ensure that all gases can be removed from the liquid impulse tube; 8. When using the isolation liquid, the liquid level of the two impulse pipes should be the same; 9. When using the injection system, the injection system should be as close as possible to the pressure intake of the process pipeline. The purified fluid passes through the same size and length pipeline to the transmitter, and the sprayed fluid should be avoided from passing through the transmitter; 10. Ensure that the impulse pipe has sufficient strength to withstand the rated working pressure; It should be noted that when the 3051 pressure transmitter measures steam or other high-temperature medium, the working temperature of the 3051 pressure transmitter should not exceed the limit, when the 3051 pressure transmitter is used for steam measurement, the impulse tube should be filled with water to prevent the transmitter from contacting steam, the volume change of the 3051 pressure transmitter is very small, and a condenser is not required. Product consultation, product customization, agent, technical inquiry, quotation, etc. If you have any questions, please contact Xingyi: 400-600-4496!
Click on the image to see the details>>
滨州市| 从化市| 长兴县| 荣昌县| 邳州市| 阜阳市| 磐安县| 响水县| 汾西县| 马山县| 梁河县| 郯城县| 隆安县| 富川| 长春市| 林芝县| 壶关县| 德格县| 湟源县| 五河县| 富宁县| 静海县| 宁强县| 司法| 专栏| 昭苏县| 永顺县| 博罗县| 射阳县| 定日县| 思南县| 聊城市| 蒙阴县| 屯昌县| 丰宁| 宜兰县| 自贡市| 大关县| 株洲市| 平定县| 玛曲县|